View Full Version : Weber cold start flooding
dodgy71
03-10-2022, 06:29 AM
When it's really cold outside the it has no high idle, cough, choke, puke, and floods itself to death, I have a block a wood I wedge against the gas pedal till it warms up while I'm waiting around. Help setting and adjusting i guess is what I'm asking for. Thanks
dodgy71
03-10-2022, 06:38 AM
...also it diesels when shut off after warmed up
SubGothius
03-10-2022, 04:01 PM
Before cold starting, press the gas pedal only once, or maybe twice if it's bitterly cold (near or below freezing temp).
A properly-tuned Weber should not diesel after shutoff, even without any idle cutoff solenoid installed. Are your spark plug tips sooty-black? Sounds like your idle mixture screw and/or jetting may be set too rich -- or possibly fuel pressure is too high, forcing fuel past the float's needle valve and into the intake. Idle jets should typically be about a size 50 (+/- 5), and this thread covers basic Weber tuning:
http://www.mightyram50.net/vbulletin/showthread.php/8669-Weber-38-on-87-mm-spx-4wd-2-6l-rejetting-help!
camoit
03-11-2022, 01:12 PM
This may also help
http://www.mightyram50.net/vbulletin/showwiki.php?title=Fuel+Management+System:Trouble+ Shooting+Weber+Carburetor